Services / EECA Compliance & Energy Retrofit

EECA 2024 (Act 861) · Akta Kecekapan dan Konservasi Tenaga 2024

EECA compliance and energy retrofit advisory for office buildings in Malaysia

Architect-certified Gross Floor Area (GFA) for your Suruhanjaya Tenaga Energy Intensity Label, and a clear, buildable path to a better BEI star rating. From the architects of Menara JKG, a 5-star BEI office building.

Does EECA apply to your building?

  • It is an office building.
  • Its Gross Floor Area is 8,000 m² or more, measured the way Suruhanjaya Tenaga defines it.
  • You have received, or expect, a written notice from Suruhanjaya Tenaga.

Not sure whether your building is above or below the threshold? A GFA certification will tell you.

Your obligations

What the person in charge of a building must do

01

Every year: apply for and display an Energy Intensity Label

The first application is due within 30 days after one year from Suruhanjaya Tenaga’s written notice. Each renewal is due within 30 days before the current label expires.

02

From year five: hold at least a 2-star rating

The minimum applies from the fifth year after the first label is issued, and must be met every year after that.

03

If the building falls short: audit and improve

Appoint a Registered Energy Auditor, submit an energy audit report with an improvement plan, and then carry out the improvements.

Two services, one team.

We certify the number your rating depends on. Then we help you improve the building behind it.

Service 01: GFA certification

EECA GFA certification by a registered architect

Borang Pengesahan Keluasan Lantai Kasar (GFA)

Suruhanjaya Tenaga requires your building’s Gross Floor Area to be certified by an architect, with signature and official stamp. Your Building Energy Intensity (BEI) is your annual energy use divided by that GFA. Getting the area right matters as much as getting the meter readings right.

EECA defines GFA differently from your building plan approval. We measure your building again against Guideline GP/ST/No.48/2024 (Pind. 1/2026).

What our GFA certification covers

  • Review your approved or as-built drawings, and walk the building where the record drawings are incomplete.
  • Set the building boundary to match where energy is metered and supplied, including tenanted floors served by your installation.
  • Measure to the outer face of external walls, or the centre line of party walls, and apply the seven permitted exclusions.
  • Prepare a floor-by-floor GFA schedule and marked-up plans showing every included and excluded area. This is your record if the figure is ever questioned.
  • Sign and stamp the Borang Pengesahan, and make sure it shows the same figure as the owner’s declaration (Lampiran A).

How Building Energy Intensity (BEI) is calculated

BEI = energy used over 12 months ÷ certified GFA

If the floor area is over-counted, your rating looks better than it is. If it is under-counted, your rating suffers for floor area you are entitled to include. Either way, the figure has to stand up.

Areas excluded from EECA GFA

  1. aParking and circulation, including M&E rooms within the parking area
  2. bOpen or covered parking outside the building
  3. cStaircases and lift shafts above the ground floor or lobby
  4. dWaiting areas for commercial vehicles loading goods
  5. eOpen or semi-open rooftop or podium gardens and recreation areas
  6. fPedestrian links to the building or a transit station
  7. gInternal pedestrian routes that work as public walkways

Star rating bands for office buildings (kWh/m²/yr)

RatingStandard officeOffice on district chilled waterIndication
5 stars90 or less190 or lessVery efficient
4 stars90–110190–240Efficient
3 stars110–160240–340Moderately efficient
2 stars (minimum)160–200340–420Slightly efficient
1 starOver 200Over 420Least efficient

Source: GP/ST/No.48/2024 (Pind. 1/2026)

Service 02: Retrofit advisory

Energy efficiency retrofit advisory for existing office buildings

An energy audit tells you what is wrong. It does not design the fix, phase it around your tenants, get it approved or get it built. That is architectural work, and it is often where improvement plans stall.

We take you from your current BEI to a target rating with measures that are costed, buildable and phased for an occupied building. You may need to clear the 2-star minimum, or you may want a higher rating for leasing and valuation. Either way, we start from the same evidence.

We work alongside

  • Your Registered Energy Manager (REM)
  • Registered Energy Auditors (REA)
  • M&E and façade engineers
  • Facility and asset managers

Already have an audit? We start from its findings. Don’t have a team yet? We will assemble one with you.

Our process

How a retrofit comes together

01

Baseline

We use twelve months of energy data, the certified GFA, a site walk and a drawing review to establish your true BEI and the gap to your target band.

02

Diagnose

We find where the building loses energy: façade and glazing, solar gain and shading, roof, daylight, space use and the plant behind them. We read these alongside the audit findings.

03

Options

We rank the possible measures by impact, cost and disruption, and set out a phasing plan that keeps floors leasable while the work goes on.

04

Deliver

We handle design, authority submissions, tender and contract administration through to completion. There is an optional path to GreenBuildingIndex (GBI) certification.

Case in point

Menara JKG

89 → 86

kWh/m²/yr BEI, 5-star held

Good performance has to be kept up. Our 2026 GBI Re-Verification Assessment of Menara JKG confirmed its BEI had improved from 89 to 86 kWh/m²/yr. It held its 5-star rating and gained further headroom below the 90 kWh/m²/yr threshold. We bring the same evidence-led approach to every retrofit.

Typical energy-saving measures we assess

External shading and finsGlazing replacement or filmRoof insulation and cool roofsDaylighting and lighting zoningAir-tightness at the envelopeRooftop solar PV integrationSpace planning and consolidationPlant room and riser reconfiguration

Why PAB

Why PAB

We design buildings to perform: Grade-A offices that reach 5 stars, and hospitals that run 24 hours a day.

Menara JKG

We were the architects of this Grade-A office building. In 2026 we completed its GreenBuildingIndex Re-Verification Assessment (RVA), which showed its BEI had improved from 89 to 86 kWh/m²/yr. That keeps it in the 5-star band, years after completion.

Energy-efficient office and government buildings

We were also the architects of GBI-rated energy-efficient buildings including Menara PJH, Platinum Sentral and Sunway Pinnacle, and the Ministry of Transport in Putrajaya.

Cyberjaya Hospital

Cyberjaya Hospital is Malaysia’s first GBI Platinum hospital. It won the Large Green Building and Energy Efficient Designed Building categories at the National Energy Awards 2026, and was named 1st Runner-Up twice at the ASEAN Energy Awards 2026.

Gleneagles Hospital Kuala Lumpur

Gleneagles Hospital Kuala Lumpur is Malaysia’s first GBI Gold hospital, rated in 2016.

Inside the rating system

Our director, Ar. David Teoh, sits on the GreenBuildingIndex Accreditation Panel. We know how performance is assessed, not just how it is designed.

Since 1974

Architecture, health facility planning, interior design, landscape architecture and town planning under one roof, so a retrofit is designed as a whole rather than trade by trade.

Audience

Who we work with

Owners and persons in charge

You need a certified GFA for your first label application, or a plan before the 2-star minimum applies.

REITs and asset managers

You have several office buildings to certify, benchmark and improve under one programme.

Energy managers and auditors

You need an architect to certify the GFA, or to design and deliver the measures in an improvement plan.

Developers

You are planning new office buildings of 8,000 m² or more and want them designed for a strong rating from day one.

FAQ

Frequently asked questions

Can’t find your answer? Talk to our team.

Who can sign the EECA GFA certification form?

The Borang Pengesahan Keluasan Lantai Kasar is signed and stamped by an architect. PAB's certifications are signed by architects registered with the Board of Architects Malaysia (LAM).

Is EECA GFA the same as the GFA on my approved building plans?

Not necessarily. EECA uses its own definition, measured to the outer face of external walls, with seven specific exclusions. The boundary also follows how energy is metered, so the figure can differ from your planning or building plan GFA.

Does EECA apply to hospitals, hotels or shopping malls?

The building labelling requirement currently covers office buildings of 8,000 m² GFA or more. Separately, large energy users of any building type may be designated as energy consumers under the Act, with their own duties. We can help you work out which applies to you.

What happens if my building is rated below 2 stars?

Suruhanjaya Tenaga may issue a notice of non-compliance. You then appoint a Registered Energy Auditor to carry out an energy audit and submit a report with an improvement plan. Our retrofit advisory turns that plan into built work.

Is PAB an energy auditor?

No. We are architects. We certify GFA and design and deliver the architectural measures, working with your Registered Energy Manager and Registered Energy Auditor.

How long does a GFA certification take?

Typically 10 working days from receipt of complete drawings, depending on the building's size and the quality of its records. We may need to visit the site where as-built drawings are incomplete.

Enquiry

Tell us about your building

Share a few details and we will advise on the next step, whether that is a GFA certification, a retrofit review or both.