Services / EECA Compliance & Energy Retrofit
EECA 2024 (Act 861) · Akta Kecekapan dan Konservasi Tenaga 2024
Architect-certified Gross Floor Area (GFA) for your Suruhanjaya Tenaga Energy Intensity Label, and a clear, buildable path to a better BEI star rating. From the architects of Menara JKG, a 5-star BEI office building.
Not sure whether your building is above or below the threshold? A GFA certification will tell you.
Your obligations
01
The first application is due within 30 days after one year from Suruhanjaya Tenaga’s written notice. Each renewal is due within 30 days before the current label expires.
02
The minimum applies from the fifth year after the first label is issued, and must be met every year after that.
03
Appoint a Registered Energy Auditor, submit an energy audit report with an improvement plan, and then carry out the improvements.
Two services, one team.
We certify the number your rating depends on. Then we help you improve the building behind it.
Service 01: GFA certification
Borang Pengesahan Keluasan Lantai Kasar (GFA)
Suruhanjaya Tenaga requires your building’s Gross Floor Area to be certified by an architect, with signature and official stamp. Your Building Energy Intensity (BEI) is your annual energy use divided by that GFA. Getting the area right matters as much as getting the meter readings right.
EECA defines GFA differently from your building plan approval. We measure your building again against Guideline GP/ST/No.48/2024 (Pind. 1/2026).
BEI = energy used over 12 months ÷ certified GFA
If the floor area is over-counted, your rating looks better than it is. If it is under-counted, your rating suffers for floor area you are entitled to include. Either way, the figure has to stand up.
| Rating | Standard office | Office on district chilled water | Indication |
|---|---|---|---|
| 5 stars | 90 or less | 190 or less | Very efficient |
| 4 stars | 90–110 | 190–240 | Efficient |
| 3 stars | 110–160 | 240–340 | Moderately efficient |
| 2 stars (minimum) | 160–200 | 340–420 | Slightly efficient |
| 1 star | Over 200 | Over 420 | Least efficient |
Source: GP/ST/No.48/2024 (Pind. 1/2026)
Service 02: Retrofit advisory
An energy audit tells you what is wrong. It does not design the fix, phase it around your tenants, get it approved or get it built. That is architectural work, and it is often where improvement plans stall.
We take you from your current BEI to a target rating with measures that are costed, buildable and phased for an occupied building. You may need to clear the 2-star minimum, or you may want a higher rating for leasing and valuation. Either way, we start from the same evidence.
Already have an audit? We start from its findings. Don’t have a team yet? We will assemble one with you.
Our process
01
We use twelve months of energy data, the certified GFA, a site walk and a drawing review to establish your true BEI and the gap to your target band.
02
We find where the building loses energy: façade and glazing, solar gain and shading, roof, daylight, space use and the plant behind them. We read these alongside the audit findings.
03
We rank the possible measures by impact, cost and disruption, and set out a phasing plan that keeps floors leasable while the work goes on.
04
We handle design, authority submissions, tender and contract administration through to completion. There is an optional path to GreenBuildingIndex (GBI) certification.
Case in point
89 → 86
kWh/m²/yr BEI, 5-star held
Good performance has to be kept up. Our 2026 GBI Re-Verification Assessment of Menara JKG confirmed its BEI had improved from 89 to 86 kWh/m²/yr. It held its 5-star rating and gained further headroom below the 90 kWh/m²/yr threshold. We bring the same evidence-led approach to every retrofit.
Why PAB
We design buildings to perform: Grade-A offices that reach 5 stars, and hospitals that run 24 hours a day.
We were the architects of this Grade-A office building. In 2026 we completed its GreenBuildingIndex Re-Verification Assessment (RVA), which showed its BEI had improved from 89 to 86 kWh/m²/yr. That keeps it in the 5-star band, years after completion.
We were also the architects of GBI-rated energy-efficient buildings including Menara PJH, Platinum Sentral and Sunway Pinnacle, and the Ministry of Transport in Putrajaya.
Cyberjaya Hospital is Malaysia’s first GBI Platinum hospital. It won the Large Green Building and Energy Efficient Designed Building categories at the National Energy Awards 2026, and was named 1st Runner-Up twice at the ASEAN Energy Awards 2026.
Gleneagles Hospital Kuala Lumpur is Malaysia’s first GBI Gold hospital, rated in 2016.
Our director, Ar. David Teoh, sits on the GreenBuildingIndex Accreditation Panel. We know how performance is assessed, not just how it is designed.
Architecture, health facility planning, interior design, landscape architecture and town planning under one roof, so a retrofit is designed as a whole rather than trade by trade.
Audience
You need a certified GFA for your first label application, or a plan before the 2-star minimum applies.
You have several office buildings to certify, benchmark and improve under one programme.
You need an architect to certify the GFA, or to design and deliver the measures in an improvement plan.
You are planning new office buildings of 8,000 m² or more and want them designed for a strong rating from day one.
The Borang Pengesahan Keluasan Lantai Kasar is signed and stamped by an architect. PAB's certifications are signed by architects registered with the Board of Architects Malaysia (LAM).
Not necessarily. EECA uses its own definition, measured to the outer face of external walls, with seven specific exclusions. The boundary also follows how energy is metered, so the figure can differ from your planning or building plan GFA.
The building labelling requirement currently covers office buildings of 8,000 m² GFA or more. Separately, large energy users of any building type may be designated as energy consumers under the Act, with their own duties. We can help you work out which applies to you.
Suruhanjaya Tenaga may issue a notice of non-compliance. You then appoint a Registered Energy Auditor to carry out an energy audit and submit a report with an improvement plan. Our retrofit advisory turns that plan into built work.
No. We are architects. We certify GFA and design and deliver the architectural measures, working with your Registered Energy Manager and Registered Energy Auditor.
Typically 10 working days from receipt of complete drawings, depending on the building's size and the quality of its records. We may need to visit the site where as-built drawings are incomplete.
Enquiry
Share a few details and we will advise on the next step, whether that is a GFA certification, a retrofit review or both.
We will contact you within the next working day.
Information on EECA 2024 reflects Suruhanjaya Tenaga guidance as of November 2026 and is not legal advice.